Home » FAQ » VFD-Motor bearing failures

VFD-Motor bearing failures

If you are not seeing typical bearing fluting from electrical discharge across the bearing/ball to the race the load and application should be looked at. Excessive radial or axial loading, tension too high on a belted load (bearing killers), shaft misalignment etc. can reduce bearing life. Most larger motors will need to be greased on a regular basis as the ambient temp, hours of operation, dirt in the atmosphere dictate. The incompatibility of greases can also cause an issue by separating. Most manufactures are using Polyrex-EM as a motor bearing lubricant. Also lubricate as to the manufactures recommended amount. Over greasing can be as detrimental as being under greased.

It has been my experience that torque instability will cause premature bearing failure. Since my team has put emphasis on adjusting the V/f output to best match the torque required by the load, we no longer experience premature bearing failures. Even when the final autopsy finds current leakage as the cause, if the races are not weakened by the continuous acceleration and deceleration caused by torque instability the path to ground is smoother reducing the damage.

If you're not seeing obvious ESD damage, the bearing life problem is likely not directly variable frequency drive (VFD) related, especially if some of the bearings are insulated. It has been my experience that whatever the most complicated piece of equipment in the system, that's what gets blamed, and VFD falls into that category.

If the bearing failures are not obviously ESD-related, what characteristics are you seeing? Are they consistent over the horsepower range of your motors? Are you operating the same switching or carrier frequency on the variable frequency drive? Have you attempted varying the lubricant? What is the ambient temperature range at the machine? Answers to these questions would lead you some very good suggestions.

Post a Comment:

    
Plz Calculate (7 * 7) =
(Your comment will show after approved.)

You may also like:

Featured Articles
Non-Enclosure Variable Frequency Drive ... Non-Enclosure Variable Frequency Drive (VFD)No enclosure (cover), reducing installation space and cost effective. Widely used in All-In-One control cabinet. Keep the same ...
Variable frequency drive application ... Variable frequency drive application guideVariable Frequency Drive (VFD) can be used in lots of fields. Variable frequency drives are widely used to control the speed of ...
Variable frequency drive in HVAC ... Variable frequency drive in HVAC systemsVariable frequency drives (VFD) have been used for HVAC systems in buildings for more than 40 years. But only in recent years, ...
Variable Frequency Drive Harmonics and ... A discussion of the benefits of variable frequency drives often leads to a question regarding electrical harmonic distortion ...
Three phase inverters Three phase invertersIn the variable frequency drive rectifier paper, it explains how to go from three phase alternating current voltage to a direct ...
Variable Frequency Drive Service
VFD manufacturers
Variable Frequency Drive Sales Email buy@vfds.org
Variable Frequency Drive Support Email tech@vfds.org